System Reset and Initialization
2-3System Resets, Interrupts, and Operating Modes
2.1.1 Brownout Reset (BOR)
All MSP430x4xx devices have a brownout reset circuit. The brownout reset
circuit detects low supply voltages such as when a supply voltage is applied
to or removed from the V
CC
terminal. The brownout reset circuit resets the
device by triggering a POR signal when power is applied or removed. The
operating levels are shown in Figure 22.
The POR signal becomes active when V
CC
crosses the V
CC(start)
level. It
remains active until V
CC
crosses the V
(B_IT+)
threshold and the delay t
(BOR)
elapses. The delay t
(BOR)
is adaptive being longer for a slow ramping V
CC.
The
hysteresis V
hys(B_ IT)
ensures that the supply voltage must drop below
V
(B_IT)
to generate another POR signal from the brownout reset circuitry.
Figure 22. Brownout Timing
t
(BOR)
V
CC(start)
V
CC
V
(B_IT)
Set Signal for
POR circuitry
V
V
(B_IT+)
hys(B_IT)
As the V
(B_IT)
level is significantly above the V
(MIN)
level of the POR circuit,
the BOR provides a reset for power failures where V
CC
does not fall below
V
(MIN).
See device-specific datasheet for parameters.