The Output Unit
11-23
Timer_B
11.5 The Output Unit
Each capture/compare block contains an output unit shown in Figure 11–22.
The output unit is used to generate output signals such as PWM signals. Each
output unit has 8 operating modes that can generate a variety of signals based
on the EQU0 and EQUx signals. The output mode is selected with the OMx
bits located in the CCTLx register.
Figure 11–22.Output Unit
D
Q
Reset
POR
OUTx
Set
Timer Clock
OUTx
OUTx Signal
EQU0
EQUx
OMx2
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
Output mode: OUTx signal reflects the value of the OUTx bit
Set mode: OUT x signal reflects the value of signal EQUx
PWM toggle/reset: EQUx toggles OUTx. EQU0 resets OUTx.
PWM set/reset: EQUx sets OUTx. EQU0 resets OUTx
Toggle: EQUx toggles OUTx signal.
Reset: EQUx resets OUTx.
PWM toggle/set: EQUx toggles OUTx. EQU0 sets OUTx.
PWM reset/set: EQUx resets OUTx. EQUx sets OUTx.
OMx1 OMx0
0
1
0
1
0
1
0
1
Output
Control
Block
Note: OUTx signal updates with rising edge of timer clock for all modes except
mode 0.
Modes 2, 3, 6, 7 not useful for output unit 0.