Vista de página 214
Timer_B Registers
11-39
Timer_B
11.6.4.4 Timer Interrupt Vector Register, Software Example, Timer_B3
The following software example describes the use of vector word TBIV of
Timer_B3 and the handling overhead. The numbers at the right margin show
the necessary cycles for every instruction. The example is written for
continuous mode: the time difference to the next interrupt is added to the
corresponding compare register.
; Software example for the interrupt part Cycles
;
; Interrupt handler for Capture/Compare Module 0.
; The interrupt flag CCIFG0 is reset automatically
;
TIMMOD0 ... ; Start of handler Interrupt latency 6
RETI 5
;
; Interrupt handler for Capture/Compare Modules 1 to 6.
; The interrupt flags CCIFGx and TBIFG are reset by
; hardware. Only the flag with the highest priority
; responsible for the interrupt vector word is reset.
TIM_HND $ ; Interrupt latency 6
ADD &TBIV,PC ; Add offset to Jump table 3
RETI ; Vector 0: No interrupt 5
JMP TIMMOD1 ; Vector 2: Module 1 2
JMP TIMMOD2 ; Vector 4: Module 2 2
RETI ; Vector 6
RETI ; Vector 8
RETI ; Vector 10
RETI ; Vector 12
;
; Timer Overflow Handler: the Timer Register is expanded
; into the RAM location TIMEXT (MSBs)
;
TIMOVH ; Vector 14: TIMOV Flag
INC TIMEXT ; Handle Timer Overflow 4
RETI 5
;
TIMMOD2 ; Vector 4: Module 2
ADD #NN,&CCR2 ; Add time difference 5
... ; Task starts here
RETI ; Back to main program 5
; The Module 1 handler shows a way to look if any other
; interrupt is pending: 5 cycles have to be spent, but
; 9 cycles may be saved if another interrupt is pending
;
TIMMOD1 ; Vector 6: Module 3
ADD #PP,&CCR1 ; Add time difference 5
... ; Task starts here
JMP TIM_HND ; Look for pending interrupts 2
;
.SECT ”VECTORS”,0FFF0h ; Interrupt Vectors
; The vector address may be different for different devices.
;
.WORD TIM_HND ; Vector for Capture/Compare
; Module 1..6 and timer overflow
; TBIFG
.WORD TIMMOD0 ; Vector for Capture/Compare
; Module 0
If the FLL (on applicable devices) is turned off, then two additional cycles need
to be added for a synchronous start of the CPU and system clock MCLK.
If the CPU clock MCLK was turned off in devices with the Basic Clock Module
(CPUOFF=1), then 2 or 3 additional cycles need to be added for synchronous
start of the CPU. The delta of one clock cycle is caused when clocks are