Reset Operation
7-25
Program Flow Control
At system reset, the following additional operations are performed:
The peripherals are reset. This is a synchronous operation. Peripheral reset
is described in Chapter 12,
Peripherals
.
The external bus control registers are reset. The reset values of the control
registers are described in Chapter 9,
’C30 and ’C31 External-Memory
Interface
.
The following CPU registers are loaded with 0:
ST (CPU status register), except in the ’C32, the PRGW status bit field
is loaded with the status of the PRGW pin
IE (CPU/DMA interrupt-enable flags)
IF (CPU interrupt flags)
IOF (I/O flags)
The reset vector is read from memory location 0h. On the ’C32, this is a
32-bit data read. Once read, this value is loaded into the PC. This vector
contains the start address of the system reset routine.
At this point, code location is dictated by the PC.
Multiple ’C3x devices, driven by the same system clock, may be reset and
synchronized. When the 1 to 0 transition of RESET occurs, the processor is
placed on a well-defined internal phase, and all of the ’C3x devices come up
on the same internal phase and all internal memory locations.
Unless otherwise specified, all registers are undefined after reset.