Texas-instruments TMS320C64x DSP Manual do Utilizador Página 58

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 306
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 57
Video Port Control Registers
2-25Video PortSPRU629
Table 29. Video Port Interrupt Status Register (VPIS) Field Descriptions (Continued)
Bit DescriptionValuesymvalfield
22 SFDB Short field detected on channel B interrupt detected bit.
BT.656 or Y/C capture mode SFDB is set when short field
detection is enabled and VCOUNT is reset before
VCOUNT = YSTOP.
Raw data mode, or TSI capture mode or display mode Not used.
NONE 0 No interrupt is detected.
CLEAR 1 Interrupt is detected. Bit is cleared.
21
VINTB2 Channel B field 2 vertical interrupt detected bit.
BT.656 or Y/C capture mode VINTB2 is set when a vertical
interrupt occurred in field 2.
Raw data mode or TSI capture mode Not used.
NONE 0 No interrupt is detected.
CLEAR 1 Interrupt is detected. Bit is cleared.
20
VINTB1 Channel B field 1 vertical interrupt detected bit.
BT.656 or Y/C capture mode VINTB1 is set when a vertical
interrupt occurred in field 1.
Raw data mode or TSI capture mode Not used.
NONE 0 No interrupt is detected.
CLEAR 1 Interrupt is detected. Bit is cleared.
19
SERRB Channel B synchronization error interrupt detected bit.
BT.656 or Y/C capture mode Synchronization parity error on
channel B. An SERRB typically requires resetting the channel
(RSTCH) or the port (VPRST).
Raw data mode or TSI capture mode Not used.
NONE 0 No interrupt is detected.
CLEAR 1 Interrupt is detected. Bit is cleared.
For CSL implementation, use the notation VP_VPIS_field_symval